E. Dold & Söhne GmbH & Co. KG
Insulation monitoring for DC charging stations with extended temperature range from -40 to +70 °C
E. Dold & Söhne GmbH & Co. KG

Insulation monitoring for DC charging stations with extended temperature range from -40 to +70 °C

all about automation Hamburg 2025

News teilen:

LinkedIn
Facebook
Twitter
WhatsApp
Insulation monitoring for DC charging stations with extended temperature range from -40 to +70 °C
E. Dold & Söhne GmbH & Co. KG

Insulation monitoring for DC charging stations with extended temperature range from -40 to +70 °C

Teilen:

Facebook
Twitter
LinkedIn
WhatsApp

Insulation monitoring for DC charging stations with extended temperature range from -40 to +70 °C

The insulation monitor RN 5897/320 of the VARIMETER IMD family from DOLD is used especially for DC charging stations according to the IEC/EN 61851-23 standard and is suitable for temperatures from -40 to +70 °C.

Insulation monitoring for DC charging stations with extended temperature range from -40 to +70 °C
DC charging stations are the first choice when electric vehicles need to be recharged within a very short time. If charging stations are installed in geographical locations with higher ambient temperatures, the electronics must be able to withstand these temperatures and function without any faults. The insulation monitor RN 5897/320 of the VARIMETER IMD family from DOLD is used especially for DC charging stations according to the IEC/EN 61851-23 standard and is suitable for temperatures from -40 to +70 °C.

It takes over the monitoring during the charging process from the charging station into the vehicle. Characteristic features of the device are the extended temperature range and the short response delay of ≤ 1s. In combination with the coupling devices RL 5898 and RP 5898, the insulation monitor is suitable for monitoring with rated voltages up to DC 500 V or DC 1000 V. The integrated voltage measurement ensures a reliable determination of the insulation resistance in the IT system. The insulation monitor also has a self-test function. This takes place automatically after power-on and after every full hour of operation.

In addition to monitoring DC charging stations, the insulation monitor RN 5897/320 can also be used for monitoring unearthed AC, DC, AC/DC mains, UPS systems, mains with frequency converters or DC drives, battery mains and mobile power generators.

Kontaktinformation

Kontaktieren Sie uns

Kontaktinformation

Kontakt-
information

Kontaktieren Sie uns

Gratis-
Ticket
sichern!

Wir freuen uns auf die aaa in Hamburg! Sie haben einen Code erhalten? Jetzt einlösen.

Sie haben noch keinen Gratisticket-Code? Jetzt anfordern